Original Research Article | OPEN ACCESS

Simultaneous Determination of Co-formulated Matrine and Secnidazole in Suppositories by Reverse Phase High Performance Liquid Chromatography

Haixia Lv, Suying Ma , Xiao Wang, Xiaojun Shang

School of Pharmacy, Xinxiang Medical University, Xinxiang Henan, 453003, PR China;

For correspondence:-  Suying Ma   Email: suyingma@163.com   Tel:+863733029879

Received: 20 February 2012        Accepted: 28 March 2013        Published: 12 June 2013

Citation: Lv H, Ma S, Wang X, Shang X. Simultaneous Determination of Co-formulated Matrine and Secnidazole in Suppositories by Reverse Phase High Performance Liquid Chromatography. Trop J Pharm Res 2013; 12(3):413-418 doi: 10.4314/tjpr.v12i3.21

© 2013 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop and validate a new, simple, sensitive and accurate high performance liquid chromatographic (HPLC) method for the simulataneous determination of matrine and secnidazole in suppositories.
Methods: The method involved using a SinoChoom ODS-BP C18 column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile–triethylamine (0.05 %) in 0.025 mol/L KH2PO4 (20:80, v/v). The flow rate was 1 mL/min and detection was monitored at 210 and 311 nm for matrine and secnidazole, respectively. Total run time was 10 min and the column was maintained at 35 oC
Results: The excipients in the suppository did not interfere with the drug peaks. Matrine was eluted at a retention time (RT) of 4.30 min while linearity for the quantification of drug was obtained in the concentration range of 10.0 - 100.0 µg/mL (r2 = 0.9991). Secnidazole was eluted at a retention time (tr) of 6.69 min and linearity for the quantification of the drug was obtained in the concentration range of 10.0 - 150.0 µg/mL (r2 = 0.9993). Intra- and inter-day variations were < 1.0 % for both matrine and secnidazole.
Conclusion: The developed HPLC method was validated according to International Conference on Harmonisation (ICH) guidelines and proved to be suitable for the simultaneous determination of matrine and secnidazole in suppositories.

Keywords: Matrine, Secnidazole, Suppository, HPLC, Assay

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates